• Measurement ranges from 0-10 ppm up to 0-100% O2
  • Accuracy of better than 2% of range
  • 24-32 months sensor life span (in normal use)
  • Up to 30 days battery life
  • Internal pump option
  • 0-1V output
  • XLT sensor options for CO2 backgrounds
  • Rugged industrial enclosures

The Model GPR-3500, packaged in a rugged enclosure, with stainless steel wetted parts, integrated flow meters and needle valves, offers purity measurement for inert gases, carbon-dioxide and oxygen.

GPR-1200 customers value the 4-way valve that allows a sample to be trapped in the sensor to speed up measurement times when moving from point to point. This analyzer feature also effectively helps to protect trace oxygen sensors from premature depletion due to exposure to ambient oxygen levels.

GPR-1200 MS-2 GPR-1200 GPR-3500 MOVR
Measurement range 0-1, 0-10, 0-100, 0-1000 ppm 0-10, 0-100, 0-1000 ppm, 0-1%
Accuracy < 3% or 10 ppb (whichever is greater) at constant conditions < 2% or 0.2 ppm (whichever is greater) at constant conditions < 2% at constant conditions
Response time T90 <10 seconds T90 <13 seconds
Sensitivity (LDL) 5 ppb 0.05ppm 0.1%
Linearity < 1% of scale
Sensor model GPR-12-2000MS-2 GPR-12-333
XLT-12-333 for gas mixture with > 0.5% CO2
Sensor life at 25ºC (77°F) and 1 atm 24 months in < 100 ppm O2 24 months in < 1000 ppm O2 24 months in 100% O2
Calibration interval 30 days
Inlet pressure 0.34 - 2 barg (5-30 psig) with atmospheric vent 248.2 barg (3600 psig)
Flow rate 0.5 - 1.0 l/m (1-2 SCFH)
Gas connections 1/8" compression tube fittings
1/4" compression tube fitting on outlet (GPR-3500-MOVR)
Wetted parts Stainless steel
Display Graphical LCD 7 x 3.5cm (2.75 x 1.375")
Resolution 0.001ppm 0.01ppm 0.1%
Enclosure Painted aluminum NEMA 4X, 21.8 x 22.9 x 7.6cm (8.6 x 9 x 3")
Weight 5.4kg (12lbs)
Compensation Barometric pressure and temperature
Signal output 0-1V
LED indicators LOW BATT (72 hr. warning);
Operating temperature GPR sensor: 5°C to 45°C (41°F to 113°F)
XLT sensor: -10°C to 45°C (14°F to 113°F)
Power Rechargeable battery (lead acid)
Battery life Up to 30 days on a single charge (40 hours with pump running, if fitted)
Area classification General purpose (safe area)
Meets standards UL: Class I, Division 1, Groups C, D
Ex ib IIB T4 Gb
Tamb +5°C to +45°C"
General purpose (safe area)
Meets standards UL: Class I, Division 1, Groups C, D
Ex ib IIB T4 Gb
Tamb -20°C to +45°C"
General purpose only

GPR-1200 & GPR-3500