*Accuracy: < 2% of FS range under constant conditions Analysis: 0-25% FS ranges
Application:
Oxygen analysis in ambient atmospheres or confined spaces 
Approvals:
EC TYPE EXAMINATION
CERTIFICATE: INERIS 08ATEX0036 
 Ex ia IIB T4 Gb
Area Classification:
 Meets the recognized intrinsic safety standards for use in
Class 1, Division 1, Group C, D hazardous  
Operating Range:
Recommended -10 ºC to 45ºC
Calibration:
Air or certified span gas
Compensation: Barometric pressure and temperature
Connections: 1/8″ compression tube fittings Controls:
Menu controls, calibration and system functions 
Display:
Graphical LCD 2.75” x 1.375”; resolution 0.1 %; displays real
time ambient temperature and pressure 
Enclosure: Painted aluminum NEMA 4X, 4”x9”x3″, 8 lbs
 Flow Sensitivity:  NA  Linearity:  ±1% of full scale
 Pressure: NA  Power:  18-24 VDC
Response Time  90% of final reading in 10 seconds  Sample System  None
Sensitivity: < 0.5% of FS range Sensor Model: GPR-11-32-4
sensor Life: 32 months at 25ºC and 1 atm. Signal Output:  4-20mA Loop Current
Warranty: 12 months analyzer; 12 months sensor Wetted Parts: Corrosion resistant materials

*At constant temperature and pressure