Accuracy: < 1% of FS range under constant conditions Analysis: 0-100 ppm, 0-25% FS ranges
Application: Oxygen analysis from 500 ppb to 1% in inert, hydrocarbon, helium, hydrogen, mixed and acid (CO2) gas streams Approvals: CE, manufacturer’s explosion proof certifications applicable
to enclosure, flame arrestors and fabrication
Area Classification: Class 1, Division 1, Groups C, D hazardous areas Alarms: None
Calibration: Certified gas of O2balance N2approximating 80% of
analysis range recommended for optimum results.
Compensation: Temperature compensated
Connections: 1/8″ compression tube fittings Controls: Integral 4-20mA zero and span pots, and, range selector
Display: LCD 3-1/2 digits; resolution .1 ppm Enclosures: Painted aluminum explosion proof NEMA 4X wall mount
with flame arrestors certified for Class 1, Division 1,
Groups C, D; 12”x8”x10”; 15 lbs
Flow Sensitivity:  None between 0.5-5 SCFH, 2 SCFH recommended Linearity:  > .995 over all ranges
Pressure: Inlet – regulate to 5-30 psig; vent – atmospheric Power: 12-28VDC two wire loop power
Recovery Time: 60 seconds in air to < 10 ppm in < 2 hours on N2purge Response Time: 90% of final FS reading in 15 seconds
Sample System: None; optional H2S sample system(s) for natural gas extraction, transmission and processing Sensitivity: < 0.5% of FS range
Sensor Model: XLT-12-100-M with > 0.5% CO2present – no maintenance Sensor Life: 24 months at 25ºC and 1 atm; average O2< 1,000 ppm
Signal Output: 4-20mA Temp. Range: -20ºto 45ºC (XLT sensor); 5º to 45ºC (GPR sensor),
Warranty: 12 months analyzer; 12 months sensor Wetted Parts: Stainless steel
Optional Equipment
Heading1 Value 1
Heading 2 Value 2
Heading 3 Value 3
Heading 4 Value 4
Heading 5 Value 5
Heading 6 Value 6
Heading 7 Value 7