Respiratory Applications

Showing 1–10 of 29 results

    PSR-11-917-M PSR-11-917-M

    Replacement for CareFusion Avea, Sipap, Flight Medical HT50, Taema Cesar Ventilator, and many more&... Replacement for CareFusion Avea, Sipap, Flight Medical HT50, Taema Cesar Ventilator, and many more…… PSR-917-M galvanic type % Respiratory oxygen sensors with excellent stability and accuracy under stringent applications. All % oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”    OEM Equipment: CareFusion Avea        CareFusion Sipap          Taema Ceasar Ventilator (old)       Versamed eVent Ventilators           GE Ivent Ventilator

    PSR-11-917-M2 PSR-11-917-M2

    Replacement galvanic oxygen sensors for use in PB 760 and PB 840 Ventilator. Click to learn moreR... Replacement galvanic oxygen sensors for use in PB 760 and PB 840 Ventilator. Click to learn more…… Advanced galvanic type % oxygen sensors with excellent stability and accuracy under stringent applications. All % oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”        OEM Equipment: PB 760 Ventilator PB 840 Ventilator

    PSR-11-75-KE4 PSR-11-75-KE4

    Replacement galvanic oxygen sensor for use in Maxtec 250K / R125P11-001 and CareFusion Vela. More... Replacement galvanic oxygen sensor for use in Maxtec 250K / R125P11-001 and CareFusion Vela. More…… Advanced PSR-11-75-KE galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All respiratory oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % respiratory oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”      OEM Equipment: Maxtec 250K / R125P11-001 CareFusion Vela

    PSR-11-75-KE13-PB PSR-11-75-KE13-PB

        Replacement oxygen sensor for PB 840, 760, 980, & 960 Ventilators and PB 10097559....     Replacement oxygen sensor for PB 840, 760, 980, & 960 Ventilators and PB 10097559. Learn more… Advanced galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”      OEM Equipment: PB 840 & 760 Ventilators PB 980 & 960 Ventilators PB 10097559 (Oxygen Sensor)  

    PSR-11-75-KE7 PSR-11-75-KE7

    (PSR-11-75-KE7-Respiratory Sensors) Replacement for Newport HT-70, e360, e500, Maxtec OM-25A, OM-24M... (PSR-11-75-KE7-Respiratory Sensors) Replacement for Newport HT-70, e360, e500, Maxtec OM-25A, OM-24ME / OM25MEL. Click to see more… Advanced galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”      OEM Equipment: Newport HT-70 Ventilator Newport e360 Ventilator Newport e500 Ventilator Maxtec OM-25A Analyzer Maxtec OM-24ME / OM25MEL Monitor Maxtec Venturi System

    PSR-11-75-KE1 PSR-11-75-KE1

    (PSR-11-75-KE1-Respiratory Sensors) Replacement galvanic oxygen sensor for use in Maxtec OM25A and V... (PSR-11-75-KE1-Respiratory Sensors) Replacement galvanic oxygen sensor for use in Maxtec OM25A and Vaportherm Precision Flow. More… Advanced galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”        OEM Equipment: Maxtec OM25A Analyzer Vaportherm Precision Flow

    PSR-11-917-MH PSR-11-917-MH

    Replacement for Criticare System Poet Monitor, Hamilton G5, Galileo, Ralphael, and Arabella. More&#... Replacement for Criticare System Poet Monitor, Hamilton G5, Galileo, Ralphael, and Arabella. More….. Advanced galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”        OEM Equipment: Criticare System Poet Monitor Hamilton G5 Ventilator Hamilton Galileo Ventilator Hamilton Ralphael Ventilator Hamilton Arabella Ventilator

    PSR-11-917-J PSR-11-917-J

    Replacement for Lifecare PLV102, MEDIX Natalcare, MSA Mini Ox, Precision Medical PM5900, and more&#... Replacement for Lifecare PLV102, MEDIX Natalcare, MSA Mini Ox, Precision Medical PM5900, and more… Advanced PSR-11-917-J galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”         OEM Equipment: Lifecare PLV102 Ventilator MEDIX Natalcare Incubator MSA Mini Ox I, II, II & 300 Analyzers / Monitors Precision Medical PM5900 and PM5900L Puritan Bennet 7820 Monitor Philips Respironics Espirit and V200 Ventilator Stephan Christina Ventilator Taema Ceasar Ventilator (newer) Teledyne AX 300 Analyzer & MX 300 Monitor

    PSR-11-915-G PSR-11-915-G

    Replacement oxygen sensor with excellent stability and accuracy for Ohmeda Giraffe Incubator. More&#... Replacement oxygen sensor with excellent stability and accuracy for Ohmeda Giraffe Incubator. More… Advanced galvanic type% oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”      OEM Equipment: Ohmeda Giraffe Incubator

    PSR-11-915-2i PSR-11-915-2i

    Replacement for Drager Baby Log Ventilators, I8000 Incubator, EVITA 2, 4, and XL Ventilators. More&... Replacement for Drager Baby Log Ventilators, I8000 Incubator, EVITA 2, 4, and XL Ventilators. More…… Advanced galvanic type % oxygen sensor with excellent stability and accuracy under stringent applications. All oxygen sensors are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of % oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”      OEM Equipment: Drager Baby Log Ventilator Drager I8000 Incubator Drager EVITA 2 Ventilator Drager EVITA 4 Ventilator Drager EVITA XL